DUCAB CATALOGUE PDF

Ducab RuBICC – H07RN-F Rubber Flexibles are designed to provide excellent flexibility during Click here to download Ducab RuBICC – H07RN-F brochure. details on lead sheath cables refer our lead sheath power, control and auxilary cable catalogue). (g). (1) XLPE insulation Ultra-violet (UV) colour masterbatch. Established in , Ducab is the leading cable manufacturing company in the This catalogue provides working information on PVC insulated wiring cables.

Author: Shashicage Kajishicage
Country: Swaziland
Language: English (Spanish)
Genre: Politics
Published (Last): 4 August 2007
Pages: 59
PDF File Size: 6.88 Mb
ePub File Size: 10.59 Mb
ISBN: 928-1-76150-837-3
Downloads: 4833
Price: Free* [*Free Regsitration Required]
Uploader: Neramar

Termite resistance can be built in both types described above by compounding with proper additives.

XLPE Insulated Low Voltage Cables

The current ratings given in relevant tables of this publication assume that cables are fully loaded i. Galvanised round steel wire GSW along with tinned copper wires TCW for maintaining specified conductivity of armour if required ctalogue the customer.

Density of XLPE is 0. Single core armoured cables to be electrically bonded at each end of the run. Experienced and highly catqlogue employees operate state-of-the-art equipment, and conduct extensive testing at every phase of production. TYPE Single and Multi-Core Flexible Cables USE Designed for indoor wiring applications, connecting handheld equipments such as power drills, hand grinders cataloguue where cables are subjected to stress by kinking and twisting.

Maximum voltage drop to be 2. Refer to page 35 and Table 31 for details.

Al Jalal Electrical Trading Est : Catalogues

The key to reliability however, is in the manufacturing process. These cables are duab for a voltage range of 1kV to 3. Again the area required depends on the characteristics of the device providing protection against short circuit.

Read Also:  PRODUCCION DE ACIDO CITRICO POR ASPERGILLUS NIGER PDF

Values of voltage drop are tabulated for a current of one ampere for a 1 metre run, i. In those cases where the actual current differs greatly from the tabulated current rating, the results obtained from the tables are only approximate; for a more accurate assessment, allowance should be made for the change in conductor resistance with operating temperature.

BT10C8 is a 10mm2 connector with a 8mm stud hole. Direct in ground – Cables touching Single way ducts – ducts touching Note: For 2 core cables, 50 mm2 and above have D-shaped conductors. Low Voltage Cables Low Voltage cables are used to supply power to large catalgoue and other industrial equipments.

Enter your details in duucab form below. Installing Ducab Smokemaster cables can reduce the threat to life by extending the escape and rescue catalogye available. Copper tape or Aluminium PE tape along with tinned copper drain wire can be used for shielding purposes.

The cable must be free from material and manufacturing defects, and weaknesses that will be revealed in service. Aluminium glands should be used in conjunction with cables having aluminium wire armour.

Account Suspended

Therefore it is possible to select a mm2 cable rather than the mm2 cable first indicated. All the cables described in this publication can be used indoors or outdoors, but some reservations are necessary concerning cables for direct burial in the ground or for use in sustained wet conditions as follows: Alternatively the most appropriate group rating factor must be applied when determining the cable size and required number of cables in parallel. For details on LSZH cables refer page e In water logged areas or where the cables are required to be abrasion resistant, cable with medium density polyethylene MDPE can be offered.

Read Also:  OFFICIAL DICTIONARY OF SARCASM PDF

XLPE insulation dissipates heat from conductors much faster as its thermal resistivity is 3. Fire Performance Cables are intended for applications requiring circuit integrity during fire. Examples are given below to illustrate situations where over-designing can be avoided. Colour of outer sheath.

Ducabb possible larger installation radii should be used. Material Galvanised round steel wire GSW. Armour bonding at both ends results in circulating current in the armour. It will be seen that this value is 0. The requirement is deemed to be actalogue if the drop in voltage from the origin of the installation usually supply terminals and the fixed current using equipment does not exceed 4 per cent of the nominal voltage of the supply, disregarding starting conditions.

Derating factor for this temp.

About Ducab Flam BICC

Let Vd be the voltage vucab in volts. These are multi-core armoured cables designed as per BS with steel wire armour construction to meet category F fire test as per BS JavaScript is not enabled in your browser.

We advice the cable diameter is measured where possible before purchasing components.

BoxManama, Kingdom of Bahrain Tel: Ducab has set improvement targets to reduce the significant environmental impacts associated with its activities. Please enable JavaScript, or certain functions may not work properly. During F fire test direct mechanical impact and water jet is provided on the cable during fire test. Retards propagation of flame in fire situation.